Software Characteristics
Various types of available instructions, as for example: indexed run with
ramp, free run with ramp, indexed run without ramp, run with a programmable
braking distance, zero research.
Space can be programmed in relative or absolute mode (linear or circular).
One instruction can be broadcasted to all drives.(broadcast mode)
Zero research procedure with a single instruction and with hardware dedicate
input.
Number of steps for indexed ramp up to +/-8.338.607 in relative or absolute
mode, speed from 1 to 24.000 Hz in standard and increased resolution, ramp
times from 16 to 1440 msec.
Availability of instructions to develop motion programs as, for example:
conditional jump, time delay, program block and recovery, I/O management,
FOR NEXT loop.
Possibility to control the execution of 16 previously stored motion programs
through hardware inputs. Accordingly, the drive can be used in stand-alone
applications, without serial connection.
Possibility to control all programs previously stored or single instructions
through the serial line.
Inputs and Outputs freely programmable with dedicated commands.